Engine-CodesFord – P1395 Ford

P1395 Ford Code - Glow Plug Monitor Fault Bank 1

Quick Answer

The P1395 diagnostic trouble code (DTC) for Ford vehicles specifically indicates a Glow Plug Monitor Fault in Bank 1. Common causes include Faulty glow plugs: The glow plugs themselves may be worn out or malfunctioning, preventing them from preheating the combustion chamber effectively, Wiring issues: Damaged or corroded wiring connections to the glow plugs can disrupt the monitoring system's operation, Faulty glow plug relay: The relay that controls the operation of the glow plugs may be faulty, leading to irregular operation. Severity is High - diagnose this code as soon as possible. Driving is not recommended if the warning light is flashing, the engine runs poorly, or safety-related symptoms are present.

What it means
P1395 Ford indicates Glow Plug Monitor Fault Bank 1.
Common causes
Common causes include Faulty glow plugs: The glow plugs themselves may be worn out or malfunctioning, preventing them from preheating the combustion chamber effectively, Wiring issues: Damaged or corroded wiring connections to the glow plugs can disrupt the monitoring system's operation, Faulty glow plug relay: The relay that controls the operation of the glow plugs may be faulty, leading to irregular operation.
Severity
High - diagnose this code as soon as possible.
Can I drive?
Driving is not recommended if the warning light is flashing, the engine runs poorly, or safety-related symptoms are present.
Table of contents Created and updated by William Orellana on Sep 10, 2024
💬 Need more help? Ask Auto Expert for instant answers — it's free!
AutoCodes App

Fix Your Car Smarter

Try the New AutoCodes App!

Get complete OBDII diagnostics, repair solutions, and cost estimates, plus AI chat support on demand.

AutoCodes App on Google Play

Code P1395 Ford Description

The P1395 diagnostic trouble code (DTC) for Ford vehicles specifically indicates a Glow Plug Monitor Fault in Bank 1. This code is typically seen in diesel engines that are equipped with glow plugs to aid in cold starting. Glow plugs are essential components that preheat the combustion chamber in diesel engines, allowing for easier starting in cold temperatures. The Glow Plug Monitor Fault Bank 1 code signifies that there is an issue with the monitoring system that oversees the operation of the glow plugs in the first cylinder bank of the engine.

OBDII Code P1395 Ford - Glow Plug Monitor Fault Bank 1
P1395 Ford Code - Glow Plug Monitor Fault Bank 1

Common Causes of P1395 Ford

  1. Faulty glow plugs: The glow plugs themselves may be worn out or malfunctioning, preventing them from preheating the combustion chamber effectively.
  2. Wiring issues: Damaged or corroded wiring connections to the glow plugs can disrupt the monitoring system's operation.
  3. Faulty glow plug relay: The relay that controls the operation of the glow plugs may be faulty, leading to irregular operation.
  4. ECM/PCM issues: A malfunction in the Engine Control Module or Powertrain Control Module can also trigger the Glow Plug Monitor Fault code.

Symptoms of P1395 Ford

  1. Extended cranking time when starting the engine, especially in cold weather.
  2. Rough idling or misfires upon startup.
  3. Reduced engine power or acceleration.
  4. Illumination of the Check Engine Light on the dashboard.
  5. Increased fuel consumption.

How to Fix P1395 Ford

  1. Diagnose the issue: Use a diagnostic scanner to retrieve the trouble codes and perform a thorough inspection of the glow plugs, wiring, and relay to identify the root cause of the problem.
  2. Replace faulty glow plugs: If the glow plugs are found to be faulty, they should be replaced with new ones to ensure proper preheating of the combustion chamber.
  3. Check wiring connections: Inspect the wiring harness for any damage or corrosion and repair or replace as necessary.
  4. Test and replace glow plug relay: Test the glow plug relay for proper functionality and replace it if it is found to be defective.
  5. Clear codes and test: After completing the repairs, clear the DTCs from the ECM/PCM memory and test the vehicle to ensure that the issue has been resolved.

Cost to Fix P1395 Ford

The cost of repairing a Glow Plug Monitor Fault Bank 1 code can vary depending on the specific cause of the issue and the labor rates in your area. On average, the cost of replacing faulty glow plugs can range from $100 to $300 per plug, depending on the make and model of your vehicle. Wiring repairs and relay replacement may add to the overall cost of the repair. The total cost, including parts and labor, can range from $300 to $800 or more. It is recommended to consult with a qualified mechanic or dealership for a more accurate estimate based on your vehicle's specific needs. Keep in mind that labor rates can vary, so it's advisable to shop around for the best pricing.

Tech Notes for P1395 Ford

California trucks it has a GPCM (Glow Plug Control Module) instead of a GPR (Glow Plug Relay).

Need more information about the P1395 Ford code?

Need more information on how to fix the P1395 Ford code? Get Access to Factory Service Manuals

Need Help with the Code?

Get the P1395 Ford code diagnosed by a professional: Find a repair shop in your area

About the author: William Orellana is a Master Mechanic and Mechanical Engineer with over 30 years of experience diagnosing and repairing vehicles. Learn more about his background.

Frequently Asked Questions about P1395 Ford Code

No Frequently Asked Questions about P1395 Ford Code found.

Discuss the causes and fixes for P1395 Ford OBDII Code

Code P1395 Ford comments