Engine-CodesAudi – P1179 Audi

P1179 Audi Code - Linear Oxygen Sensor Pump Current Short To Ground

Quick Answer

The P1179 Audi code indicates a problem with the linear oxygen sensor pump current being shorted to ground. Common causes include Damaged wiring or connectors, Faulty linear oxygen sensor pump, Corroded connectors. Severity is High - diagnose this code as soon as possible. Driving is not recommended if the warning light is flashing, the engine runs poorly, or safety-related symptoms are present.

What it means
P1179 Audi indicates Linear Oxygen Sensor Pump Current Short To Ground.
Common causes
Common causes include Damaged wiring or connectors, Faulty linear oxygen sensor pump, Corroded connectors.
Severity
High - diagnose this code as soon as possible.
Can I drive?
Driving is not recommended if the warning light is flashing, the engine runs poorly, or safety-related symptoms are present.
Table of contents Created and updated by William Orellana on Sep 10, 2024
💬 Need more help? Ask Auto Expert for instant answers — it's free!
AutoCodes App

Fix Your Car Smarter

Try the New AutoCodes App!

Get complete OBDII diagnostics, repair solutions, and cost estimates, plus AI chat support on demand.

AutoCodes App on Google Play

Code P1179 Audi Description

The P1179 Audi code indicates a problem with the linear oxygen sensor pump current being shorted to ground. The oxygen sensor, also known as the O2 sensor, is responsible for monitoring the oxygen levels in the exhaust gases and providing feedback to the engine control module (ECM) to adjust the air-fuel mixture for optimal combustion. When the sensor pump current is shorted to ground, it means that the signal being sent by the sensor is not reaching the ECM properly, which can lead to incorrect fuel trim adjustments and potentially affect the vehicle's performance.

OBDII Code P1179 Audi - Linear Oxygen Sensor Pump Current Short To Ground
P1179 Audi Code - Linear Oxygen Sensor Pump Current Short To Ground

Common Causes of P1179 Audi

  1. Damaged wiring or connectors
  2. Faulty linear oxygen sensor pump
  3. Corroded connectors
  4. Short circuit in the sensor circuit
  5. ECM malfunction

Symptoms of P1179 Audi

  1. Poor fuel economy
  2. Decreased engine performance
  3. Rough idling or stalling
  4. Check Engine Light illuminated
  5. Increased emissions

How to Fix P1179 Audi

  1. Begin by diagnosing the issue using a scan tool to verify the P1179 code and check the sensor's wiring and connectors for any damage or corrosion.
  2. If any damage is found, repair or replace the wiring and connectors as necessary.
  3. Test the linear oxygen sensor pump to ensure it is functioning correctly. Replace the sensor if it is faulty.
  4. Clear the fault codes from the ECM and perform a test drive to verify that the issue has been resolved.
  5. If the problem persists, further diagnostics may be required to pinpoint the exact cause of the short to ground.

Cost to Fix P1179 Audi

The typical repair costs for addressing a P1179 Audi code can vary depending on the extent of the damage and the parts needed for replacement. On average, the repair for this issue can range from $200 to $500, including parts and labor. It's important to note that diagnosis time and labor rates at auto repair shops can vary, so it's advisable to check with local shops for a more accurate estimate based on your specific vehicle make and model.

Need more information about the P1179 Audi code?

Need more information on how to fix the P1179 Audi code? Get Access to Factory Service Manuals

Need Help with the Code?

Get the P1179 Audi code diagnosed by a professional: Find a repair shop in your area

About the author: William Orellana is a Master Mechanic and Mechanical Engineer with over 30 years of experience diagnosing and repairing vehicles. Learn more about his background.

Frequently Asked Questions about P1179 Audi Code

1. What does the OBDII code P1179 mean on an Audi?

P1179 indicates a "Linear Oxygen Sensor Pump Current Short to Ground," meaning there is an electrical issue with the oxygen sensor circuit, typically involving a short.

2. What are the common symptoms of P1179 in an Audi?

Symptoms may include poor engine performance, rough idling, reduced fuel efficiency, the Check Engine Light turning on, and difficulty passing emissions tests.

3. What causes the P1179 code to appear in an Audi?

Common causes include damaged wiring or connectors in the oxygen sensor circuit, a faulty linear oxygen sensor, or an issue with the engine control module (ECM).

4. Can a bad oxygen sensor trigger the P1179 code?

Yes, a malfunctioning linear oxygen sensor can cause this code if it fails to regulate the pump current correctly or has a short circuit.

5. How do you diagnose the P1179 code on an Audi?

Start by inspecting the wiring and connectors for damage or corrosion, check the oxygen sensor for faults, and verify ECM functionality using a diagnostic tool.

6. Can driving with a P1179 code damage my Audi?

Driving with this code may cause poor engine performance and increased emissions, but prolonged driving could lead to more severe engine or catalytic converter issues.

7. How do you fix the P1179 code on an Audi?

Repairs may include replacing or repairing damaged wiring, connectors, or the linear oxygen sensor, and updating or replacing the ECM if necessary.

8. How much does it cost to repair the P1179 code in an Audi?

Repair costs vary, but replacing an oxygen sensor typically costs $200-$400, while more extensive wiring repairs or ECM replacements can cost significantly more.

9. Can the P1179 code clear itself after repairs?

Yes, once the root issue is fixed, the code may clear itself after a few drive cycles. Alternatively, you can clear it manually using an OBDII scanner.

10. Is the P1179 code specific to Audis?

While the code can appear on other vehicles, its definition and troubleshooting steps are tailored to Audi's systems and linear oxygen sensor design.

Discuss the causes and fixes for P1179 Audi OBDII Code

Code P1179 Audi comments