Engine-Codes - Mercury - B1082 Mercury

B1082 Mercury Code - Right Temperature Damper Motor Circuit

- Code Popularity: 780 Views
- Repair Importance Level: 3/3
- Repair Difficulty Level: 3/3
Table of contents
ChatAC AutoCodes.com AI Chat

What are the Possible Causes of the DTC B1082 Mercury?

NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
  • Faulty Right Temperature Damper Motor
  • Right Temperature Damper Motor harness is open or shorted
  • Right Temperature Damper Motor circuit poor electrical connection
  • Faulty Heating, Ventilation, and Air Conditioning (HVAC) Module

Code Tech Notes

B1082:11 - Right Temperature Damper Motor: Circuit Short to Ground
B1082:12 - Right Temperature Damper Motor: Circuit Short to Battery
B1082:13 - Right Temperature Damper Motor: Circuit Open

⚠ Does your Mercury have Safety Recalls? → Check here

How to Fix the DTC B1082 Mercury?

Check the 'Possible Causes' listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.

Search for B1082 Mercury Questions and Answers: Search here →

What is the Cost to Diagnose the Code?

Labor: 1.0

The cost to diagnose the B1082 Mercury code is 1.0 hour of labor. The diagnosis time and labor rates at auto repair shops vary depending on the location, make and model of the vehicle, and even the engine type. Most auto repair shops charge between $75 and $150 per hour.

What are Code Possible Symptoms?

  • Engine Light ON (or Service Engine Soon Warning Light)

What Does the B1082 Mercury Code Mean?

To rotate the temperature blend door actuator, the Heating, Ventilation, and Air Conditioning (HVAC) Module supplies voltage and ground to the temperature blend door actuator through the door actuator motor circuits. To reverse the temperature blend door actuator rotation, the HVAC module reverses the voltage and ground circuits.
The temperature blend door actuator feedback resistors are supplied a ground from the HVAC module by the temperature blend door actuator return circuits and a 5-volt reference voltage on the temperature blend door actuator reference circuits. The HVAC module reads the voltage on the temperature blend door actuator feedback circuits to determine the temperature blend door actuator position by the position of the actuator feedback resistor wiper arm.
During an actuator calibration cycle, the HVAC module drives the temperature blend door until the door reaches both internal stops in the HVAC case. If the temperature blend door is temporarily obstructed or binding during a calibration cycle, the HVAC module may interpret this as the actual end of travel for the door. When this condition occurs and the HVAC module commands the actuator to its end of travel, the airflow may not be the expected temperature.

B1082 Mercury Code - Right Temperature Damper Motor Circuit

Need more Information on the Code?

Need more information on how to fix the B1082 Mercury code? Get Access to Factory Service Manuals

Need Help with the Code?

Get the B1082 Mercury code diagnosed by a professional: Find a repair shop in your area